DescriptionThis applet demonstrates an interrupt-based counter
realized with the PIC16C84 microcontroller.
In the default settings, the clock generator for the PIC16C84
runs at 1 KHz only, in order to save host CPU time.
The second clock generator component is used to generate the
pulses we want to count. Naturally, you could use any other data source.
The microcontroller program is very simple.
It first initializes the counter register and enables interrupts
on port B0. Afterwards, it enters an endless loop that does nothing.
The interrupt routine in turn increments the counter variable,
outputs the lower 4 bits of the counter value to ports B7..B4,
re-enables interrupts, and returns:
TITLE "16-Bit-Zaehler: PIC16C84"
SUBTITLE "Zaehlimpulse von RB0/INT"
;***********************************************************************
; A simple interrupt-driven counter program. It counts rising-edge
; events on port B0 and outputs the lower 4 bits of the counter value
; on ports B7...B4.
; Note that the watchdog timer WDT needs to be disabled to run this
; program, because WDT interrupts are not handled.
;***********************************************************************
Processor 16C84
Radix DEC
EXPAND
include "p16c84.inc"
_ResetVector set 0x00
_IntVector set 0x04
Zaehler set 0x20
ORG _ResetVector ; the program starts here
call Init ; initialize ports, counter, and interrupts
InfiniteLoop:
goto InfiniteLoop ; idle loop
ORG _IntVector ; interrupt-address
goto Interrupt ; handle interrupt
;***********************************************************************
; enable B3..B0 as inputs and B7..B4 as outputs.
; enable interrupts for RB0/INT and reset the counter variable.
;***********************************************************************
Init:
bsf STATUS, RP0 ; select bank 1
movlw 0xC0 ; rising edge sensitive, no pullup for
movwf OPTION ; RB0/INT-PIN
movlw 0x10 ; only enable RB0/INT interrupt
movwf INTCON ; INTCON is in both banks
movlw 0x0F ; set B3..B0 as inputs, B7..B4 as outputs
movwf TRISB ; move into the direction control register
bcf STATUS, RP0 ; select bank 0
clrf Zaehler ; clear counter value
retfie ; RETURN and enable interrupts
;***********************************************************************
; very simple interrupt handler.
; We do not even need to save and restore the work register or status bits.
; Increment the counter and output the lower 4 bits on port B.
;***********************************************************************
Interrupt:
incf Zaehler ; increment counter values
swapf Zaehler,W ; swap nibbles of counter, result in W
movwf PORTB ; write W to port B
bsf STATUS, RP0 ; select bank 1
movlw 0x10 ; select RB0/INT interrupts only
movwf INTCON ; move to interrupt control register
bcf STATUS, RP0 ; select bank 0
retfie ; return from interrupt handler